Conforms to API 526 Snap Acting and Modulating Control Actuation Semi and Full Port Nozzle Design Typical Blowdown of 3-6%
Farris 3800 General Specifications:
Size 1” x 2” to 12” x 16” API Orifice Areas D (0.15 sq2) to T (26.0 sq2) Non-API Orifice Areas A, 1-8 (45.66 sq2) Set Pressure Ranges 15 to 6170
API Orifice Areas D (0.15 sq2) to T (26.0 sq2) Non-API Orifice Areas A, 1-8 (45.66 sq2) Set Pressure Ranges 15 to 6170
Set Pressure Ranges 15 to 6170 psig (1.0 to 425 barg) Temperature Ranges -320 to 500°F (-195 to 260°C) Flange Classes 150# – 2500# Suitable for Air, Gas, Vapor, Steam & Liquid Service Materials of Construction Carbon Steel
Temperature Ranges -320 to 500°F (-195 to 260°C) Flange Classes 150# – 2500# Suitable for Air, Gas, Vapor, Steam & Liquid Service Materials of Construction Carbon Steel
Flange Classes 150# – 2500# Suitable for Air, Gas, Vapor, Steam & Liquid Service Materials of Construction Carbon Steel
Materials of Construction Carbon Steel, Stainless Steel, Low/High-Temperature Alloy Steels, Monel, Hastelloy C, Duplex, NACE Compliant Materials
Accessories:
- Dual Pilot
- Reverse Flow Preventer
- Field Test Connection
- Remote Depressurizing
- Auxiliary Filters
- Consult Catalog for additional accessories
Certifications
- ASME/NB Section VIII and III for Air, Steam and Water
- CSA B51 (Canada CRN)
- ISO 9001- 2008
- PED 97/23/EC (European Pressure Equipment Directive)
- ATEX 94/9/EC (European Potentially Explosive Atmospheres)
- CSQL (China)
- GOST-R (Russian)
- US Coast Guard
- Nuclear – 10 CRF 50 Appendix B, NCA-4000, NQA-1 N285.0
- First Point Assessment Limited